A furnace that will not turn on is most often set wrong at the thermostat, switched off, tripped at the breaker, or shut down by its own safety controls after the filter clogs. Bryant and Carrier, the furnace makers, both start there. Work through the checks below in order, and if you smell gas, stop and leave the house.
If the checks do not fix it, the work belongs to a certified gas technician, and the time to compare the HVAC companies in Ottawa is now.
On this page
Past those checks, compare companies before you need one, so you are not choosing one from a cold house at 10 at night.
What stops a furnace from turning on
Bryant sorts the causes into three groups. The first two are mostly yours to check. The third is not:
- Power and controls: the thermostat on the wrong mode or with dead batteries, the furnace switch turned off, a tripped breaker or a blown fuse. A gas furnace still needs electricity to run.
- Airflow and safety shutdowns: a clogged filter or blocked registers can overheat the heat exchanger until the limit switch shuts the burner off. On a high-efficiency furnace, a blocked condensate drain can trip a float switch that keeps the furnace from running.
- Ignition and gas: a pilot light gone out on an older furnace, a failed electronic igniter, a dirty flame sensor, or no gas reaching the furnace.
If the fan runs but the air is cold
Then the furnace is turning on and failing to light. Carrier says a fan that works with no heat points to the burner or the ignition. If you hear the small inducer fan start and the burners never light, Carrier names the ignition or a pressure switch.
A click with no flame means the same thing, by Bryant's account: the igniter is trying and failing. None of these is a homeowner fix, but the thermostat and filter checks below still come first, because they are free.
Water on the floor beside it is a different problem with its own checks: see our guide to a furnace leaking water.
Why an Ottawa winter puts the outside vents on the list
Snow is the local cause the makers' checklists leave out. Enbridge Gas, which supplies Ottawa's natural gas, puts the appliance vents outside on its own list of things to check before you call a contractor about a house with no heat.
Its vent safety page says snow, ice or debris can block appliance vents and make them malfunction. After a storm, clear the vent pipes on the outside wall with a broom or a soft brush, never a shovel, a blower or anything sharp, and knock down large icicles hanging above them. If you cannot clear the buildup safely, Enbridge asks you to call it at 1-866-763-5427.
Why it pays to sort it out in November
Everyone else's furnace fails in the same weeks. The directory's own Google Ads pull for Ottawa, taken on 10 September 2026, counted 320 searches for furnace repair in October 2025, 880 in December and 1,000 in January 2026.
If the house has no heat at all, one Enbridge rule helps. When cold weather arrives, a registered HVAC contractor can order a "Rush" service request from Enbridge, as long as the home is occupied and nothing but portable heaters is warming it, or the heating equipment carries a valid warning tag or cannot be repaired. Ask the contractor you book whether it applies.
How to check a furnace that will not turn on
This order follows Enbridge's pre-call list and the two makers' checklists. None of it needs a tool or a burner panel off:
- Thermostat. Set it to heat and a few degrees above the room temperature. Replace the batteries if it uses them.
- Furnace switch. It looks like a light switch, on the side of the furnace or a wall nearby, and it must be on.
- Breaker or fuse. Reset a tripped breaker once, or replace a blown fuse. If it trips again, leave it off and call.
- Filter. Turn the furnace switch off first, slide in a clean filter with its arrows pointing toward the furnace, and close the access panel before you switch the power back on.
- Registers and returns. Open the supply registers and move furniture and rugs off the return grilles.
- Outside vents. Brush away snow and ice from the vent pipes on the outside wall.
- Gas. Check whether the stove or water heater works. If they do not either, call Enbridge about the supply. Never touch the gas valve.
- Pilot light, on an older furnace. Relight it only by the instructions on the furnace or in the maker's booklet.
- Status light. Write down any blinking pattern and the model number from the rating plate. Bryant says the codes differ by model, so read them in your owner's manual.
Resetting it once, the right way
Carrier's reset is plain: turn the furnace switch or the breaker off, wait 30 seconds, and turn it back on. Some furnaces also have a reset button on the burner box, the rollout switch, which pops when the unit overheats. Carrier says to press it, and to call a dealer if it trips again right away.
One reset is a test. A second is a guess, because a safety control that trips twice has found something real.
What never to do
- Reset the same breaker or button over and over. Bryant says repeated safety shutdowns need a professional diagnosis.
- Bypass or jumper a safety switch. Bryant says a limit switch should not be bypassed, and neither should the condensate safety switch on a high-efficiency furnace.
- Open the burner compartment or work on the gas valve.
- Use a furnace that carries a red tag. Under O. Reg. 212/01, section 13, an appliance found to be an immediate hazard has its gas shut off and a written direction that it not be used until the condition is corrected. Our furnace maintenance guide for Ottawa explains the tags.
- Keep troubleshooting if you smell gas, see smoke or flames, or suspect an electrical fault.
When it is a gas technician's call
Anything past the list above is. Section 6 of O. Reg. 212/01 says no one may repair or service a gas appliance without a certificate. Enbridge says it does not repair furnaces itself, and sends you to the Technical Standards and Safety Authority and the Heating, Refrigeration and Air Conditioning Institute of Canada to check a contractor's certification.
Gas is a different call. Enbridge says a rotten-egg smell or a hissing sound means leave the house, without touching phones, switches or electronics, and call 1-866-763-5427 or 911 from outside. A carbon monoxide alarm detects carbon monoxide, not natural gas, so treat an alarm as its own reason to get out.
Who to call, and what to have ready
Start with the Ottawa companies listed for furnace repair. Bryant suggests giving the technician the model number, any blink code, any sound, and when the problem started. Ask what the diagnostic visit costs and whether that fee comes off the work.
Our guide to the cost of each furnace fault in Ottawa lists published diagnostic fees with each publisher named. If the technician says the furnace is near the end, read how long a furnace lasts before you agree to a big repair.
Common questions
Is there a reset button on a furnace?
How do I force my furnace to start?
How many times can you reset a furnace?
Why is my furnace blowing cold air?
Why is gas not getting to my furnace?
Will a furnace run if the pilot light is out?
Why does my furnace start and then shut off?
When is a furnace that will not turn on an emergency?
Smell gas near the furnace? Leave the house first, then call Enbridge from outside.
Enbridge gas leak stepsSources
Each page read 16 November 2026.
- Bryant, Why is my furnace not turning on?
- Carrier, Your guide to a furnace not turning on (13 October 2026)
- Enbridge Gas, Heating with gas: before you call a contractor, and rush service
- Enbridge Gas, Keep your meter and vents clear
- Enbridge Gas, Smell natural gas? What to do right away
- Government of Ontario, O. Reg. 212/01, Gaseous Fuels, sections 6 and 13